Support
- Home /
- Support
FAQ
What is the maximum working pressure of GWS tanks?
| Pressure Tanks | Bar | PSI |
|---|---|---|
| Challenger | 10 | 150 |
| PressureWave | 10 | 150 |
| C2Lite-CAD | 8.6 | 125 |
| Max | 16 | 230 |
| UltraMax | 25 | 360 |
| SuperFlow | 10 / 16 / 25 | 150/ 230 / 360 |
| FlowThru | 8.6 | 125 |
| All-Weather | 10 | 150 |
| M-Inox | 6 | 87 |
| HydroGuard | 7 | 100 |
| Heating Tanks | Bar | PSI |
|---|---|---|
| HeatWave | 6 | 87 |
| SolarWave | 10 | 150 |
| ThermoWave | 10 | 150 |
What is the maximum working temperature of GWS tanks?
| Pressure Tanks | °C | °F |
|---|---|---|
| PressureWave | 90 | 194 |
| Challenger | 90 | 194 |
| C2Lite-CAD | 49 | 120 |
| Max | 90 | 194 |
| UltraMax | 90 | 194 |
| SuperFlow | 90 | 194 |
| FlowThru Steel | 90 | 194 |
| FlowThru Composite | 49 | 120 |
| All-Weather | 90 | 194 |
| M-Inox | 90 | 194 |
| HydroGuard | 90 | 194 |
| Heating Tanks | °C | °F |
|---|---|---|
| HeatWave | 99 | 210 |
| SolarWave | 130 | 266 |
| ThermoWave | 90 | 194 |
Can I use glycol (anti-freeze) in a GWS tank?
We recommend not using over a 50/50 mix. of propylene glycol. Ethylene glycol shall not be used. Under no circumstances can the product contain a petroleum base.
Can I use petroleum base products in my GWS tanks?
No. The material in our diaphragm will not tolerate petroleum-based products.
Can I install my GWS tank on its side?
Tanks larger than 100 liters are not recommended for installation on their side since it may cause diaphragm damage and failure.
What is the warranty on GWS tanks?
GWS warranty varies by market- please contact your local distributor for warranty applicable in your area.
Does the warranty cover labor?
No, unfortunately there are number of factors that can contribute to a failed tank and the only factor that GWS can insure is the tank.
My tank was just installed and the water has a funny taste – what should I do?
Flush the new tank by allowing water to flow through three or four pump cycles. If the taste continues, you should probably have the source water tested.
Can I use chlorinated water with my GWS tank?
Of course. GWS tanks are designed in the knowledge that chlorine is often used to periodically treat a well.
What is a cycle?
A cycle refers to the pump run time. A cycle starts when the pump starts and a cycle is completed when the pump stops. Pump starts and stops are determined by the pressure settings of the system. Below, we demonstrate a tank’s drawdown feature that assumes a water system with a 30/50-psi pressure setting. This means that the pump will start (“cut-in”) whenever the pressure inside a tank is reduced to 30 psi and will stop (“cut-out”) when the pressure reaches 50 psi. Common pressure settings are 20/40, 30/50 and 40/60.
How does a pressure switch control the pump and tank?
The pressure switch communicates with the tank and the pump. The pressure switch monitors the pressure inside the tank and activates and de-activates the pump when cut-in and cut-out pressures are reached inside the tank.
What is drawdown?
Drawdown refers to the amount of water that evacuates the tank before the pressure switch will activate the pump. Drawdown is a affected by the pump, the size of the tank and the pressure settings that govern your water system.
What is pre-charge pressure?
Pre-charge pressure refers to the amount of gas (air is used in GWS tanks) in bar/psi that is pumped into a tank prior to installation – usually at the factory. The pre-charge is the “spring” that helps to create water pressure. As the diaphragm fills with water, it compresses the pre-charge. In a 30/50 system, the pump will continue to propel water into the tank until the pressure in the tank reaches 50 psi.
What is the standard pre-charge GWS tanks provided with?
| Pressure Tanks | Bar | PSI |
|---|---|---|
| PressureWave | 1.9 | 28 |
| Challenger | 1.4 | 20 |
| C2Lite-CAD | 1.4 | 20 |
| Max | 4 | 58 |
| UltraMax | 4 | 58 |
| SuperFlow | 4 | 58 |
| FlowThru | 1.4 | 20 |
| All-Weather | 1.9 | 28 |
| M-Inox | 1.9 | 28 |
| HydroGuard | 1 & 4 | 15 & 58 |
| Heating Tanks | Bar | PSI |
|---|---|---|
| HeatWave (2 – 24 liter) | 0.7 | 10 |
| HeatWave (35 liter) | 1 | 15 |
| HeatWave (60 – 150 liter) | 1.5 | 22 |
| SolarWave | 1.9 | 28 |
| ThermoWave | 1.9 | 28 |
How much pressure (pre-charge) should be in my tank?
Your tanks should be pressurized to 2 psi less than the cut-in pressure setting (for example, if your pressure settings are 30/50, then you cut-in pressure setting is 30 psi and your tank should have a 28 psi pre-charge).
How do I check or change my pre-charge?
You must completely drain the tank to check pre-charge. To do this, shut the power off to the pump and open (turn-on) a faucet in the house. This will drain the tank and not allow it to refill. On the top of the tank you will find an air valve (similar to the air valve on your tires) – use a tire pressure gauge to check the air pressure.
What is the maximum chlorine tolerance of the diaphragms?
We recommend 5 – 50 ppm for flowing treatment and a maximum of 250 ppm for system disinfection.
How to connect a FlowThru tank to a bigger or smaller diameter pipe?
The pipe diameter should be changed to the connection diameter 50cm before and after the tank.
FAQ
What is the OneStop+ series designed for?
OneStop+ is designed to protect plumbin and water-using equipment from limescale, including water heaters, fixtures, showers and coffee machines. The range includes point-of-use (POU) cartridge systems, residential point-of-entry (POE) systems and larger commercial POE systems.
How does OneStop+ work?
The treatment media converts dissolved hardness minerals into microscopic crystals that remain suspended in the water. These crystals have a reduced tendency to attach to surfaces, helping limit the formation of hard scale in pipes and equipment.
How does OneStop+ differ from a water softener?
OneStop+ conditions hardness minerals to help protect against scale, while leaving them in the water. It provides scale protection without ion exchange or sodium. For applications that need a specific reduction in water hardness, a water softener or another treatment solution may be required.
Will a hardness test still show hard water?
OneStop+ conditions hardness minerals to help protect against scale while leaving them in the water. A standard hardness test measures the minerals present, so hard water readings are expected - even when OneStop+ is working effectively.
Does OneStop+ need salt, electricity or backwashing?
No. OneStop+ operates without salt, electricity, regeneration or backwashing and does not produce regeneration wastewater. Some water may need to be discharged during commissioning and servicing as explained in the installation manual.
Does OneStop+ make untreated water safe to drink?
OneStop+ is designed for use with water that is already suitable for drinking. It is not a disinfection system or a complete water purifier. If your water needs additional treatment, a water treatment specialist will be able to recommend a suitable solution.
What is the difference between POU and POE systems?
POU (Point Of Use) systems treat water immediately before an individual outlet or appliance. Residential POE (Point Of Entry) systems treat the supply entering a home or feeding selected equipment. Commercial POE systems serve higher-flow building or equipment supplies. Select the configuration for the area you want to protect and the flow it needs.
Which models are available, and what flow can they handle?
The flow ratings below distinguish normal service from intermittent peak use. Select a system for the expected demand, water temperature and operating pattern, with guidance from your OneStop+ dealer.
| Model family | Service flow L/min | Intermittent peak flow L/min |
| Point-of-Use (POU) | ||
| OSP-10SB / OSP-10SN | 3 | 5 |
| OSP-10JB / OSP-10JN | 8 | 12 |
| OSP-20JB / OSP-20JN | 15 | 22 |
| Residential Point-of-Entry (POE) | ||
| OSP-1024B / N | 50 | - |
| OSP-1054B / N | 76 | - |
| OSP-1252B / N | 114 | - |
| Commercial Point-of-Entry (POE) | ||
| OSP-1465 | Temperature dependent | 189 |
| OSP-1665 | Temperature dependent | 303 |
Commercial intermittent duty means less than 2 hours at maximum flow in any 24-hour period. For continuous duty, use the temperature-specific sizing chart in the commercial manual. A dash indicates no separate peak rating is given.
What connections do the systems use?
POU models have ¾-inch BSPP or NPT connections. Residential POE models have a 1-inch inlet/outlet head, with B versions using BSPP and N versions using NPT. Commercial OSP-1465 and OSP-1665 systems use 2-inch PVC socket connections.
Can OneStop+ protect a water heater or boiler?
Yes. It can be installed on the cold-water feed before a water heater or suitable boiler, within the system’s operating limits. For steam generation, closed-loop circuits or other specialist applications, contact GWS to confirm suitability before selecting a system.
Should the water be tested before installation?
Yes, if the water chemistry is unknown, particularly for private wells. Compare the analysis with all water chemistry limits in the manual for your model. Excess iron, manganese and other contaminants can foul the media and reduce its effectiveness.
What are the main water chemistry limits?
OneStop+ requires a pH of 6.5–8.5, maximum hardness of 1,300 ppm, maximum ferrous iron of 0.3 ppm, maximum manganese of 0.05 ppm and chlorine below 3 ppm. These are not the only suitability criteria: phosphate, calcium sulphate, oil, polyphosphates and hydrogen sulphide also need to be assessed before installation.
Can OneStop+ be combined with other water treatment?
Yes, with the correct treatment sequence. Install OneStop+ as the final treatment stage before the plumbing or equipment requiring scale protection. Separate POU filters, such as drinking-water carbon or reverse osmosis systems, are exceptions to this treatment sequence. Ask your installer to confirm the arrangement for your application.
Are phosphates or other antiscalants compatible?
Do not dose phosphate or other antiscalants before or after OneStop+. If these substances are already present in the supply, ask a water treatment specialist to assess pretreatment. Your installer should check the phosphate-related prefiltration requirements in the relevant manual for your water supply.
What water temperatures can the systems handle?
POU cartridge systems operate at 4–40°C (40–104°F). Residential and commercial POE tank systems operate at 4–49°C (40–120°F). Install on the cold-water supply and protect the system from freezing. Commercial continuous-duty flow ratings also depend on incoming water temperature.
What does installation involve?
An authorized GWS dealer or GWS-approved installer should install and service your system, following the model-specific manual and local plumbing codes. The system must be upright and level, with a way to bypass or isolate it for servicing. POU systems arrive with the cartridge installed; POE tank systems require the separately supplied media to be loaded before commissioning. Your installer will also check the pressure limits for your model.
Will OneStop+ remove existing limescale?
OneStop+ can help reduce existing limescale deposits over time. The result depends on the installation and condition of the plumbing. It should not be treated as a guaranteed or immediate replacement for any cleaning or servicing required by the appliance manufacturer.
Why can I still see spots or residue after treatment?
Hardness minerals remain in the water. If water evaporates from glass, fixtures or a pan, mineral residue can remain. Deposits should generally be easier to wipe away than untreated hard scale. OneStop+ is designed to reduce hard scale formation, rather than provide mineral-free or completely spot-free water.
Will OneStop+ improve taste or remove chloride?
OneStop+ is designed primarily for scale protection. It does not remove chloride and should not be selected as a treatment for taste or odour problems. Where these are a concern, ask your dealer to recommend additional treatment based on your water analysis.
Do I need to change my detergent use?
You may be able to use less dishwasher detergent. We recommend initially reducing dishwasher detergent by approximately 50% compared with hard-water use, then adjusting to suit the results. A rinse aid may help. Follow the appliance and detergent instructions; commercial laundry and warewashing chemicals should be reviewed with the chemical supplier.
How often should the cartridge or media be replaced?
Replacement timing depends on water use, water quality and the application. Ask your dealer to set an appropriate service and replacement schedule for your model. POU units use replacement cartridges, while POE tank systems are serviced by replacing the treatment media.
What should I do if hard scale returns?
Contact your dealer to check the cartridge or media, water chemistry, operating flow and installation. Hardness test results alone cannot confirm whether replacement is needed. For service or warranty support, have your model number, serial number where applicable and installation date available.
FAQ
Can I drink the water produced by the ZeroSpot?
No, DO NOT drink the water treated by this system. This water is deionized and not suitable for human consumption.
What kind of water can be used with the ZeroSpot?
Please use filtered water or city water.
Can I use hot water to supply the ZeroSpot?
DO NOT use hot water with this system. While the maximum rated system temperature is 40 °C / 104 °F, we do not recommend using the system for hot water rinsing applications.
If I am using the ZeroSpot with a pressure washer or pump, should I install before or after the pressure washer or pump?
The ZeroSpot should be installed before the pressure washer or pressure pump. Please ensure to purge hose connections installed after the ZeroSpot and run water through the unit before drawing with a pressure washer.
As the max draw/flow rate of consumer-grade pressure washers may vary, please first check to ensure the pressure washer specifications are compatible with the ZeroSpot, which has maximum flow rate of 9.5 LpM (2.5 GpM).
If used with pressure washer that has a higher draw/flow rate than the ZeroSpot, or with a pressure washer that requires the use of a holding tank, then it is recommended for the user to fill a clean auxiliary holding tank that is dedicated for deionized water and not connect the pressure washer directly to the ZeroSpot.
If used incorrectly or with an incompatible pressure washer (in terms of flow rate), there is a risk of cavitation which may/will cause damage to the ZeroSpot.
Is the ZeroSpot system supplied with a garden hose and sprayer?
No, these items are not included with the ZeroSpot system.
Can I use the ZeroSpot with my old garden hose?
Yes, but you should ensure the old garden hose and sprayer are purged of old water prior to installing ZeroSpot. Old water may contain hard minerals and leave water spots on your car. If purging an old hose is not possible, then use a separate garden hose and sprayer specifically for the ZeroSpot system.
What should I do with the exhausted media? Is the media landfill safe?
The exhausted media is categorized as non-hazardous commercial waste and is landfill safe. Please also consult with your local waste collection service for the relevant disposal policy.
I can see a recommendation to restrict the flowrate to one (1) gallon per minute, or 4.5 liters per minute. What is your recommendation for reducing the flowrate?
We recommend the use of a standard spray nozzle with a flat or center spray setting to limit the flowrate. Additionally, we also recommend using a flow restrictor.
What type of resin is used in the ZeroSpot system?
The ZeroSpot resin is a strong-acid cation/strong-base anion mixed-bed exchange resin.
What is the expected system capacity and cartridge life?
Please refer Treatment Capacity Table.
| Treatment Capacity Table – Recommended rinse parameters (45 psi / 4.5 LpM) | ||||
| Feed Water TDS (ppm) | Treated water (L) | Treated water (gal) | # of rinses @ 3 minutes of spray | # of rinses @ 5 minutes of spray |
| 25 | 3750 | 991 | 278 | 167 |
| 50 | 1875 | 495 | 139 | 83 |
| 100 | 938 | 248 | 69 | 42 |
| 150 | 703 | 186 | 52 | 31 |
| 200 | 469 | 124 | 35 | 21 |
| 250 | 375 | 99 | 28 | 17 |
| 300 | 313 | 83 | 23 | 14 |
| 350 | 268 | 71 | 20 | 12 |
| 400 | 234 | 62 | 17 | 10 |
If I use the ZeroSpot with extremely hard water, what should I expect in terms of system capacity and cartridge life?
Using ZeroSpot with extremely hard water will cause the system to become exhausted at a faster rate.
What is the proper way to store the ZeroSpot system when not in use?
If the system is not being used, store the system indoors. For storage, avoid exposure to direct sunlight and protect from the elements. Avoid freezing to prevent damaging the system.
Do you have any tips for storing the ZeroSpot system when not in use for long periods of time?
If the system is not being used for more than 3 weeks, relieve hose pressure, open the housings using supplied wrench, remove cartridges and empty water from housings. Place cartridges in a location that will not create water damage, i.e., a sink or drain. Allow cartridges to drain completely before returning them to the housings.
What is the expected shelf life of the resin cartridges?
The resin cartridges have a shelf life of more than two years. After two years, the resin’s capacity will gradually start to decline at a rate of approximately 3-5% per year.
FAQ
How do I install a carbon filter?
Insert the carbon filter into the housing and tighten the cap. Run water through the housing for 3 minutes, then close the tap. After 5 minuts open the tap and allow the water to run for 5 minutes. This will completely flush the cartridge. During the flushing you will note black / grey water containing carbon fines.